Use the > key to scroll to the zone you wish to bypass.The System Must be disarmed prior to proceeding.
![dsc alarm panel manual how to bypass zone dsc alarm panel manual how to bypass zone](https://cdn.shopify.com/s/files/1/1659/9809/files/DSC-PK5508.jpg)
#DSC ALARM PANEL MANUAL HOW TO BYPASS ZONE SERIES#
Here’s step-by-step instructions on how to bypass zones on your DSC Power Series Security alarm panel: These include low batteries on devices, construction, or animals or pets. There are many reasons you many wish to bypass a zone, which means that the system will disregard any alarms from that zone when armed. This is applicable if you use your system at home or for your business or commercial security alarm system. Today, we’ll look at how to bypass a zone with a DSC Power Series Security Alarm panel. Welcome to a new, regular feature from Fire Monitoring of Canada! In these posts, we’ll walk you through “How-To’s” for equipment that we service, and questions that we are regularly asked from you, our customers. Ready Light (green) – If the Ready light is on, the system is ready for arming.Īrmed Light (red) – If the Armed light is on, the system has been armed successfully. System Trouble – This icon is displayed when a system trouble is active. System - Indicates one or more of the following : Night – Indicates that the panel is armed in the Night Mode. System Trouble – Indicates that a system trouble is active. When zones are opened, the OPEN icon will turn on, and 7 segment displays 1 and 2ĪC – Indicates that AC is present at the main panel. OPEN – This icon is used with clock digits 1 and 2 to indicate violated zones (not alarm) on the
![dsc alarm panel manual how to bypass zone dsc alarm panel manual how to bypass zone](https://cms.dsc.com/media/documents/thumbnails/l_PC2500_closed_red_circle.jpg)
When a zone is in alarm, the ALARM icon will turn on, and 7 segment displays 1 and 2 will time.ĪLARM – This icon is used with clock digits 1 and 2 to indicate zones in alarm on the system. These icons will notīe on if the system is programmed for 24 Hr. It will turn off when the chime function key is pressed again to disable Door Chime.ĪM, PM – This icon indicates that the local clock is displaying 12 Hr. Stay – Indicates that the panel is armed in the Stay Mode.Ĭhime – This icon turns on when the Chimeįunction key is pressed to enable Door Chime on Program – indicates that the system is in Installer’s Programming, or the keypad is busy.Īway – Indicates that the panel is armed in the Away Mode.įire – Indicates that there are fire alarms in memory. Memory – Indicates that there are alarms in memory.īypass – Indicates that there are zones automatically or manually bypassed. : (Colon) – This icon is the hours/minutes divider and will flash once a second when the localĬlock Digits 3, 4 – These two 7 segment displays are the minute digits when the local clock isġ to 8 – These numbers identify troubles when
![dsc alarm panel manual how to bypass zone dsc alarm panel manual how to bypass zone](https://s1.manualzz.com/store/data/001605423_1-8e5b9f9206ac2946c7e9e0984aa78eb0.png)
Its scroll one zone per second from the lowest zone number to the highest when scrolling Clock Digits 1, 2 – These two 7 segment clock digits indicate the hour digits when the localĬlock is active, and identify the zone when the OPEN or ALARM icons are active.